MAIN |
Range of product |
Telemecanique Emergency stop rope pull switches XY2C |
Product or component type |
Latching emergency stop rope pull switch |
Device short name |
XY2CE |
Housing colour |
Red RAL 3000 |
Overvoltage category |
Class I conforming to EN/IEC 61140 Class I conforming to NF C 20-030 |
COMPLEMENTARY |
Local signalling |
Without pilot light |
Number of cables |
1 |
Trigger cable maximum length |
70 m |
Body material |
Zamak |
Cover material |
Stainless steel |
Reset |
By booted push-button |
Contacts type and composition |
1 NC + 1 NO |
Contact operation |
Slow-break |
Trigger cable anchor point |
LH side |
Connections - terminals |
Screw clamp terminal, 1 x 0.5...2 x 1.5 mm² |
Tightening torque |
0.8…1.2 N.m |
Cable entry number |
3 plain hole for Pg 13.5 or ISO M20 cable gland |
Safety level |
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 |
Safety reliability data |
B10d = 300000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear |
Marking |
CE |
Mechanical durability |
60000 cycles |
Distance between cable supports |
5 m |
[Ie] rated operational current |
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A |
[Ithe] conventional enclosed thermal current |
10 A |
[Ui] rated insulation voltage |
500 V (pollution degree 3) conforming to EN/IEC 60947-1 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to EN/IEC 60947-1 |
Positive opening |
With conforming to EN/IEC 60947-5-1 |
Maximum resistance across terminals |
25 MOhm conforming to EN/IEC 60255-7 category 3 25 MOhm conforming to NF C 93-050 method A |
Short-circuit protection |
10 A cartridge fuse type gG conforming to EN/IEC 60269 |
Terminals description ISO n°1 |
(21-22)NC (13-14)NO |
Net weight |
1.45 kg |
Compatibility code |
XY2CE |
ENVIRONMENT |
Standards |
EN/IEC 60947-5-1 UL 508 CSA C22.2 No 14 Work equipment directive 2009/104/EC EN/IEC 60204-1 EN/ISO 13850 Machinery directive 2006/42/EC EN/IEC 60947-5-5 |