General-purpose Limit switches, General load, IP67, SPDT, Roller plunger, VCTF 3 m, Front mounting
Shape/Structure |
General-purpose Limit switches
|
Actuator |
Roller plunger
|
Electrical ratings |
5 A at 250 VAC/ 4 A at 30 VDC
|
Contact form |
SPDT
|
Cable specifications |
VCTF, 4 cores, 3 m
|
Degree of protection |
IP67 |
Shape/Structure |
General-purpose Limit switches |
ctuator |
Roller plunger 12 dia. x 4.4 Sintered stainless steel roller |
Electrical ratings |
5 A at 250 VAC/ 4 A at 30 VDC |
Frequency |
50/60 Hz |
Contact form |
SPDT |
Load |
General load |
Ratings (AC): Non-Inductive load |
Resistive load: 5 A at 125 VAC/5 A at 250 VAC Lamp load (NC): 1.5 A at 125 VAC/1 A at 250 VAC Lamp load (NO): 7 A at 125 VAC/0.5 A at 250 VAC Inductive load: 3 A at 125 VAC/2 A at 250 VAC Motor load (NC): 2.5 A at 125 VAC/1.5 A at 250 VAC Motor load (NO): 1.3 A at 125 VAC/0.8 A at 250 VAC |
Ratings (DC): Non-Inductive load |
Resistive load: 5 A at 8 VDC/5 A at 14 VDC/4 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDC Lamp load: 2 A at 8 VDC/2 A at 14 VDC/2 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDC Inductive load (NC): 5 A at 8 VDC/4 A at 14 VDC/3 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDC Inductive load (NO): 4 A at 8 VDC/4 A at 14 VDC/3 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDC Motor load: 3 A at 8 VDC/3 A at 14 VDC/3 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDC |
Inrush current |
NC: 20 A max. NO: 10 A max. |
Earth terminal |
With earth wire |
Cable specifications |
VCTF, 4 cores, 3 m Nominal sectional area: 0.75 mm2 Diameter: 7.6 dia. |
Ambient temperature |
Operating: -10 to 70 ℃ (with no icing) |
Ambient humidity |
35 to 95% RH |
Permissible operating speed |
0.1 mm/s to 0.5 m/s |
Permissible operating frequency |
Electrical: 30 operations / 1 minute max. Mechanical: 120 operations / 1 minute max. |
Contact resistance (Initial value) |
300 mΩ max. |
Insulation resistance |
100 MΩ min. (at 500 VDC) |
Dielectric strength |
Between each terminal of the same polarities: 1,000 VAC 50/60 Hz 1 min Between live-metallic part and ground: 1,500 VAC 50/60 Hz 1 min Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz 1 min |
Impulse withstand voltage |
Between live-metallic part and ground: 2.5 kV Between each terminal and non-live-metallic part: 2.5 kV |
Durability |
Electrical: 200,000 operations min. (5 A at 125 VAC) Mechanical: 10 million operations min. |
Vibration resistance |
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude |
Shock resistance |
Destruction: 1,000 m/s2 max. Malfunction: 500 m/s2 max. |
Pollution degree |
3 (EN60947-5-1) |
Degree of protection |
IP67 |
Classification of protection against electric shock |
Class I (with earth wire) |